{"product_id":"pn2092-ifm-pressure-sensor-industrial-pressure-sensor-kmspare","title":"PN2092 IFM Pressure Sensor | Industrial Pressure Sensor – KMSPARE","description":"\u003ch3 data-start=\"114\" data-end=\"217\"\u003e\u003cstrong data-start=\"118\" data-end=\"217\"\u003eIFM Pressure Sensor | 0–100 bar | IO-Link + Analog Output | Dual Digital Outputs | G 1\/4 Thread\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"219\" data-end=\"293\"\u003e\u003cstrong data-start=\"219\" data-end=\"293\"\u003eReliable Pressure Sensing for High-Performance Industrial Applications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"295\" data-end=\"625\"\u003eThis IFM pressure sensor is engineered for robust industrial use, offering high-precision measurement up to 100 bar (1450 psi). With IO-Link compatibility, analog and dual digital outputs, and a ceramic-capacitive measuring element, it ensures exceptional stability, overload protection, and flexibility in demanding environments.\u003c\/p\u003e\n\u003chr data-start=\"627\" data-end=\"630\"\u003e\n\u003ch4 data-start=\"632\" data-end=\"656\"\u003e✅ \u003cstrong data-start=\"639\" data-end=\"656\"\u003eKey Features:\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cul data-start=\"658\" data-end=\"1180\"\u003e\n\u003cli data-start=\"658\" data-end=\"739\"\u003e\n\u003cp data-start=\"660\" data-end=\"682\"\u003e\u003cstrong data-start=\"660\" data-end=\"680\"\u003eMeasuring Range:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"685\" data-end=\"739\"\u003e\n\u003cli data-start=\"685\" data-end=\"701\"\u003e\n\u003cp data-start=\"687\" data-end=\"701\"\u003e0 to 100 bar\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"704\" data-end=\"721\"\u003e\n\u003cp data-start=\"706\" data-end=\"721\"\u003e0 to 1450 psi\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"724\" data-end=\"739\"\u003e\n\u003cp data-start=\"726\" data-end=\"739\"\u003e0 to 10 MPa\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"741\" data-end=\"924\"\u003e\n\u003cp data-start=\"743\" data-end=\"763\"\u003e\u003cstrong data-start=\"743\" data-end=\"761\"\u003ePressure Type:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"766\" data-end=\"924\"\u003e\n\u003cli data-start=\"766\" data-end=\"787\"\u003e\n\u003cp data-start=\"768\" data-end=\"787\"\u003eRelative pressure\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"790\" data-end=\"834\"\u003e\n\u003cp data-start=\"792\" data-end=\"834\"\u003eVacuum resistance: -1000 mbar (-0.1 MPa)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"837\" data-end=\"880\"\u003e\n\u003cp data-start=\"839\" data-end=\"880\"\u003eMax Pressure Rating: 300 bar (4350 psi)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"883\" data-end=\"924\"\u003e\n\u003cp data-start=\"885\" data-end=\"924\"\u003eBursting Pressure: 650 bar (9400 psi)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"926\" data-end=\"1044\"\u003e\n\u003cp data-start=\"928\" data-end=\"949\"\u003e\u003cstrong data-start=\"928\" data-end=\"947\"\u003eSuitable Media:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"952\" data-end=\"1044\"\u003e\n\u003cli data-start=\"952\" data-end=\"967\"\u003e\n\u003cp data-start=\"954\" data-end=\"967\"\u003e\u003cstrong data-start=\"954\" data-end=\"965\"\u003eLiquids\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"970\" data-end=\"1044\"\u003e\n\u003cp data-start=\"972\" data-end=\"1044\"\u003e\u003cstrong data-start=\"972\" data-end=\"981\"\u003eGases\u003c\/strong\u003e (conditionally suitable for use above 25 bar – upon request)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1046\" data-end=\"1180\"\u003e\n\u003cp data-start=\"1048\" data-end=\"1072\"\u003e\u003cstrong data-start=\"1048\" data-end=\"1070\"\u003eSensor Technology:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1075\" data-end=\"1180\"\u003e\n\u003cli data-start=\"1075\" data-end=\"1121\"\u003e\n\u003cp data-start=\"1077\" data-end=\"1121\"\u003eCeramic-capacitive pressure measuring cell\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1124\" data-end=\"1180\"\u003e\n\u003cp data-start=\"1126\" data-end=\"1180\"\u003eGold-plated contacts for improved signal reliability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1182\" data-end=\"1185\"\u003e\n\u003ch4 data-start=\"1187\" data-end=\"1226\"\u003e⚙️ \u003cstrong data-start=\"1195\" data-end=\"1226\"\u003eOutputs \u0026amp; Electrical Specs:\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cul data-start=\"1228\" data-end=\"1939\"\u003e\n\u003cli data-start=\"1228\" data-end=\"1652\"\u003e\n\u003cp data-start=\"1230\" data-end=\"1252\"\u003e\u003cstrong data-start=\"1230\" data-end=\"1248\"\u003eTotal Outputs:\u003c\/strong\u003e 3\u003c\/p\u003e\n\u003cul data-start=\"1255\" data-end=\"1652\"\u003e\n\u003cli data-start=\"1255\" data-end=\"1429\"\u003e\n\u003cp data-start=\"1257\" data-end=\"1281\"\u003e\u003cstrong data-start=\"1257\" data-end=\"1279\"\u003e2 Digital Outputs:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1286\" data-end=\"1429\"\u003e\n\u003cli data-start=\"1286\" data-end=\"1310\"\u003e\n\u003cp data-start=\"1288\" data-end=\"1310\"\u003ePNP\/NPN configurable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1315\" data-end=\"1363\"\u003e\n\u003cp data-start=\"1317\" data-end=\"1363\"\u003eOutput mode: Normally open \/ normally closed\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1368\" data-end=\"1391\"\u003e\n\u003cp data-start=\"1370\" data-end=\"1391\"\u003eMax current: 250 mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1396\" data-end=\"1429\"\u003e\n\u003cp data-start=\"1398\" data-end=\"1429\"\u003eSwitching frequency: \u0026lt; 500 Hz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1433\" data-end=\"1570\"\u003e\n\u003cp data-start=\"1435\" data-end=\"1457\"\u003e\u003cstrong data-start=\"1435\" data-end=\"1455\"\u003e1 Analog Output:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1462\" data-end=\"1570\"\u003e\n\u003cli data-start=\"1462\" data-end=\"1500\"\u003e\n\u003cp data-start=\"1464\" data-end=\"1500\"\u003eCurrent: 4–20 mA (max load: 500 Ω)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1505\" data-end=\"1543\"\u003e\n\u003cp data-start=\"1507\" data-end=\"1543\"\u003eVoltage: 0–10 V (min load: 2000 Ω)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1548\" data-end=\"1570\"\u003e\n\u003cp data-start=\"1550\" data-end=\"1570\"\u003eScalable 1:5 range\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1574\" data-end=\"1652\"\u003e\n\u003cp data-start=\"1576\" data-end=\"1652\"\u003e\u003cstrong data-start=\"1576\" data-end=\"1588\"\u003eIO-Link:\u003c\/strong\u003e Supported (for enhanced data communication and configuration)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1654\" data-end=\"1691\"\u003e\n\u003cp data-start=\"1656\" data-end=\"1691\"\u003e\u003cstrong data-start=\"1656\" data-end=\"1678\"\u003eOperating Voltage:\u003c\/strong\u003e 18–30 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1692\" data-end=\"1728\"\u003e\n\u003cp data-start=\"1694\" data-end=\"1728\"\u003e\u003cstrong data-start=\"1694\" data-end=\"1718\"\u003eCurrent Consumption:\u003c\/strong\u003e \u0026lt; 35 mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1729\" data-end=\"1939\"\u003e\n\u003cp data-start=\"1731\" data-end=\"1757\"\u003e\u003cstrong data-start=\"1731\" data-end=\"1755\"\u003eProtection \u0026amp; Safety:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1760\" data-end=\"1939\"\u003e\n\u003cli data-start=\"1760\" data-end=\"1791\"\u003e\n\u003cp data-start=\"1762\" data-end=\"1791\"\u003eReverse polarity protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1794\" data-end=\"1831\"\u003e\n\u003cp data-start=\"1796\" data-end=\"1831\"\u003eShort-circuit protection (pulsed)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1834\" data-end=\"1857\"\u003e\n\u003cp data-start=\"1836\" data-end=\"1857\"\u003eOverload protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1860\" data-end=\"1885\"\u003e\n\u003cp data-start=\"1862\" data-end=\"1885\"\u003eProtection Class: III\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1888\" data-end=\"1911\"\u003e\n\u003cp data-start=\"1890\" data-end=\"1911\"\u003eIntegrated watchdog\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1914\" data-end=\"1939\"\u003e\n\u003cp data-start=\"1916\" data-end=\"1939\"\u003ePower-on delay: 0.3 s\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1941\" data-end=\"1944\"\u003e\n\u003ch4 data-start=\"1946\" data-end=\"1986\"\u003e🛠️ \u003cstrong data-start=\"1955\" data-end=\"1986\"\u003eMechanical \u0026amp; Environmental:\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cul data-start=\"1988\" data-end=\"2309\"\u003e\n\u003cli data-start=\"1988\" data-end=\"2105\"\u003e\n\u003cp data-start=\"1990\" data-end=\"2015\"\u003e\u003cstrong data-start=\"1990\" data-end=\"2013\"\u003eProcess Connection:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"2018\" data-end=\"2105\"\u003e\n\u003cli data-start=\"2018\" data-end=\"2063\"\u003e\n\u003cp data-start=\"2020\" data-end=\"2063\"\u003eG 1\/4 internal thread (DIN EN ISO 1179-2)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2066\" data-end=\"2105\"\u003e\n\u003cp data-start=\"2068\" data-end=\"2105\"\u003eRotatable for flexible installation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2107\" data-end=\"2161\"\u003e\n\u003cp data-start=\"2109\" data-end=\"2140\"\u003e\u003cstrong data-start=\"2109\" data-end=\"2138\"\u003eMedium Temperature Range:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"2143\" data-end=\"2161\"\u003e\n\u003cli data-start=\"2143\" data-end=\"2161\"\u003e\n\u003cp data-start=\"2145\" data-end=\"2161\"\u003e-25°C to +80°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2163\" data-end=\"2309\"\u003e\n\u003cp data-start=\"2165\" data-end=\"2189\"\u003e\u003cstrong data-start=\"2165\" data-end=\"2187\"\u003eIndustrial Design:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"2192\" data-end=\"2309\"\u003e\n\u003cli data-start=\"2192\" data-end=\"2249\"\u003e\n\u003cp data-start=\"2194\" data-end=\"2249\"\u003eBuilt for long-term performance in harsh environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2252\" data-end=\"2309\"\u003e\n\u003cp data-start=\"2254\" data-end=\"2309\"\u003eExcellent signal stability and high overload capacity\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2311\" data-end=\"2314\"\u003e\n\u003ch4 data-start=\"2316\" data-end=\"2353\"\u003e📦 \u003cstrong data-start=\"2324\" data-end=\"2353\"\u003eRecommended Applications:\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cul data-start=\"2355\" data-end=\"2510\"\u003e\n\u003cli data-start=\"2355\" data-end=\"2388\"\u003e\n\u003cp data-start=\"2357\" data-end=\"2388\"\u003eHydraulic \u0026amp; pneumatic systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2389\" data-end=\"2428\"\u003e\n\u003cp data-start=\"2391\" data-end=\"2428\"\u003eIndustrial machinery and automation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2429\" data-end=\"2468\"\u003e\n\u003cp data-start=\"2431\" data-end=\"2468\"\u003eProcess monitoring in fluid systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2469\" data-end=\"2510\"\u003e\n\u003cp data-start=\"2471\" data-end=\"2510\"\u003eOEM equipment and high-pressure lines\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2512\" data-end=\"2515\"\u003e\n\u003cp data-start=\"2517\" data-end=\"2707\"\u003e\u003cstrong data-start=\"2517\" data-end=\"2707\"\u003eA versatile and durable solution for advanced pressure monitoring—trusted in industrial environments where reliability matters. Built by IFM for performance, precision, and productivity.\u003c\/strong\u003e\u003c\/p\u003e","brand":"KMSpare Link Pvt. Ltd.","offers":[{"title":"Default Title","offer_id":50687247778086,"sku":null,"price":0.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0947\/9097\/5782\/files\/PN2092_IFM_Pressure_Sensor_Industrial_Pressure_Sensor_KMSPARE.jpg?v=1766144831","url":"https:\/\/kmspare.com\/products\/pn2092-ifm-pressure-sensor-industrial-pressure-sensor-kmspare","provider":"KMSpare Link Pvt. Ltd. - Complete Electronics \u0026 Smt Solutions","version":"1.0","type":"link"}