{"product_id":"sa2000-ifm-flow-sensor-accurate-industrial-flow-monitoring-kmspare","title":"SA2000 IFM Flow Sensor – Accurate Industrial Flow Monitoring | KMSPARE","description":"\u003cp\u003eNumber of inputs and outputs Number of digital outputs: 2; Number of analogue outputs: 1\nProcess connection threaded connection G 1\/2 external thread\nApplication\nSpecial feature Gold-plated contacts\nMedia water; glycol solutions; air; oils\nNote on media \nlow-viscosity oils with viscosity: ? 40 mm²\/s (40 °C)\nhigh-viscosity oils with viscosity: \u0026gt; 40 mm²\/s (40 °C)\nMedium temperature[°C] -20...90\nPressure rating \n100 bar 10 MPa\nMAWP for applications according to CRN[bar] 85\nElectrical data\nOperating voltage[V] 18...30 DC\nCurrent consumption[mA] \u0026lt; 100\nProtection class III\nReverse polarity protection yes\nPower-on delay time[s] 10\nMeasuring principle calorimetric\nInputs \/ outputs\nNumber of inputs and outputs Number of digital outputs: 2; Number of analogue outputs: 1\nOutputs\nTotal number of outputs 2\nOutput signal switching signal; analogue signal; frequency signal; IO-Link; (configurable)\nElectrical design PNP\/NPN\nNumber of digital outputs 2\nOutput function normally open \/ normally closed; (parameterisable)\nMax. voltage drop switching output DC[V] 2.5\nPermanent current rating of switching output DC[mA] 250\nNumber of analogue outputs 1\nAnalogue current output[mA] 4...20; (scalable)\nMax. load[?] 350\nShort-circuit protection yes\nType of short-circuit protection pulsed\nOverload protection yes\nFrequency of the output[Hz] 0...1000\nMeasuring\/setting range\nProbe length L[mm] 19.2\nOperating mode relative; absolutely liquid; absolutely gaseous; (absolute: reference measurement recommended; Factory setting: relative)\nTemperature monitoring\nMeasuring range[°C] -20...90\nResolution[°C] 0.2\nLiquid media - absolute operating mode\nSetting range[m\/s] 0.04...3\nGreatest sensitivity[m\/s] 0.04...3\nLiquid media - relative operating mode\nSetting range[m\/s] 0.04...6\nGreatest sensitivity[m\/s] 0.04...3\nGases - operating mode \"absolute\"\nSetting range[m\/s] 0...100\nGreatest sensitivity[m\/s] 30...100\nGases - operating mode \"relative\"\nSetting range[m\/s] 0...200\nGreatest sensitivity[m\/s] 30...100\nAccuracy \/ deviations\nTemperature drift[cm\/s x 1\/K] 0,003 m\/s x 1\/K (\u0026lt; 20 °C; \u0026gt; 70 °C)\nTemperature gradient[K\/min] 100\nAbsolute operating mode\nRepeatability 0,05 m\/s; (water; flow velocity: 0,05...3 m\/s)\nRelative operating mode\nAccuracy ± (7 % MW + 2 % MEW); (for relative mode in the range of maximum sensitivity under the following conditions:; water: 20...70 °C; inlet length: 1.5 m; DN25 (DIN 2448); mounting position according to instructions; Accuracy can differ for other media and mounting positions.)\nRepeatability 0,05 m\/s; (water; flow velocity: 0,05...3 m\/s)\nTemperature monitoring\nTemperature drift ± 0,005 K\/°C\nAccuracy[K] ± 0,3 \/ ± 1; (water; flow velocity: 0,3...3 m\/s \/ air; flow velocity: \u0026gt; 10 m\/s)\nResponse times\nResponse time[s] 0.5; (T09; water; glycol: 0,8 s; air: 7 s; oil: 1,8 s; each T09)\nTemperature monitoring\nDynamic response T05 \/ T09[s] 1,5 (T09); (water; flow velocity: 0,3...3 m\/s)\nSoftware \/ programming\nParameter setting options hysteresis \/ window; normally open \/ normally closed; switching logic; current\/frequency output; medium selection; Damping; Teach function; display can be rotated and switched off; standard unit of measurement; process value colour\nInterfaces\nCommunication interface IO-Link\nTransmission type COM2 (38,4 kBaud)\nIO-Link revision 1.1\nSDCI standard IEC 61131-9\nSIO mode yes\nRequired master port type A\nProcess data analogue 2\nProcess data binary 2\nMin. process cycle time[ms] 3\nSupported DeviceIDs \nType of operation DeviceID\nFactory setting \/ ModE = (REL) 535\nModE = (GAS) 547\nModE = (LIQU) 540\nFactory setting \/ ModE = (REL)\nProfiles \nSmart Sensor - SSP 0 Generic Profiled Sensor\nFunction Device identification\nFunction Multiple switching signal\nFunction Device diagnosis\nFunction Teach channel\nModE = (GAS)\nProfiles \nSmart Sensor - SSP 0 Generic Profiled Sensor\nFunction Device identification\nFunction Process data variable\nFunction Device diagnosis\nModE = (LIQU)\nProfiles \nSmart Sensor - SSP 0 Generic Profiled Sensor\nFunction Device identification\nFunction Process data variable\nFunction Device diagnosis\nOperating conditions\nAmbient temperature[°C] -40...80\nStorage temperature[°C] -40...100\nProtection IP 65; IP 67\nTests \/ approvals\nEMC \nDIN EN 60947-5-9 \nShock resistance \nDIN EN 60068-2-27 50 g (11 ms)\nVibration resistance \nDIN EN 60068-2-6 20 g (10...2000 Hz)\nMTTF[years] 143\nUL approval \nUL approval no. I003\nFile number UL E174189\nMechanical data\nWeight[g] 270\nHousing cylindrical\nDimensions[mm] Ø 34 \/ L = 123.9\nMaterials stainless steel (316L\/1.4404); stainless steel (301\/1.4310); PBT-GF20; PBT-GF30\nMaterials (wetted parts) stainless steel (316L\/1.4404); Gasket: FKM\nProcess connection threaded connection G 1\/2 external thread\nProbe diameter[mm] 5\nInstallation length EL[mm] 19.2\nDisplays \/ operating elements\nDisplay \nDisplay unit 6 x LED, green (%, m\/s, l\/min, m³\/h, °C, 10³)\nswitching status 2 x LED, yellow\nmeasured values alphanumeric display, red\/green 4-digit\nRemarks\nRemarks \nMW = measured value\nMEW = Final value of the measuring range\nPack quantity 1 pcs.\nElectrical connection\nConnection Connector: 1 x M12; coding: A; Contacts: gold-plated\u003c\/p\u003e","brand":"KMSpare Link Pvt. Ltd.","offers":[{"title":"Default Title","offer_id":50548771488038,"sku":null,"price":0.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0947\/9097\/5782\/files\/SA2000_IFM_Flow_Sensor_Accurate_Industrial_Flow_Monitoring_KMSPARE.jpg?v=1768477477","url":"https:\/\/kmspare.com\/products\/sa2000-ifm-flow-sensor-accurate-industrial-flow-monitoring-kmspare","provider":"KMSpare Link Pvt. Ltd. - Complete Electronics \u0026 Smt Solutions","version":"1.0","type":"link"}