{"product_id":"sm4000-ifm-flow-meter-industrial-liquid-flow-sensor-kmspare","title":"SM4000 IFM Flow Meter | Industrial Liquid Flow Sensor | KMSPARE","description":"\u003cp\u003eNumber of inputs and outputs Number of digital outputs: 2; Number of analogue outputs: 1\nMeasuring range \n5...3000 ml\/min 0.005...3 l\/min\nProcess connection threaded connection G 1\/4 external thread DN6 flat seal\nApplication\nSpecial feature Gold-plated contacts\nApplication totaliser function; for industrial applications\nInstallation connection to pipe by means of an adapter\nMedia conductive liquids; water; hydrous media\nNote on media \nconductivity: ? 20 µS\/cm\nviscosity: \u0026lt; 70 mm²\/s (40 °C)\nMedium temperature[°C] 0...60\nPressure rating \n10 bar 1 MPa\nMAWP for applications according to CRN \n8.6 bar 0.86 MPa\nElectrical data\nOperating voltage[V] 18...30 DC; (to SELV\/PELV)\nCurrent consumption[mA] \u0026lt; 80\nProtection class III\nReverse polarity protection yes\nPower-on delay time[s] 5\nMeasuring principle magnetic-inductive\nInputs \/ outputs\nNumber of inputs and outputs Number of digital outputs: 2; Number of analogue outputs: 1\nInputs\nInputs counter reset\nOutputs\nTotal number of outputs 2\nOutput signal switching signal; analogue signal; pulse signal; IO-Link; (configurable)\nElectrical design PNP\/NPN\nNumber of digital outputs 2\nOutput function normally open \/ normally closed; (parameterisable)\nMax. voltage drop switching output DC[V] 2\nPermanent current rating of switching output DC[mA] 200\nNumber of analogue outputs 1\nAnalogue current output[mA] 4...20; (scalable)\nMax. load[?] 500\nAnalogue voltage output[V] 0...10; (scalable)\nMin. load resistance[?] 2000\nPulse output flow rate meter\nShort-circuit protection yes\nType of short-circuit protection pulsed\nOverload protection yes\nMeasuring\/setting range\nMeasuring range \n5...3000 ml\/min 0.005...3 l\/min\nDisplay range[ml\/min] -1999...3600\nResolution[ml\/min] 1\nSet point SP[ml\/min] 20...3000\nReset point rP[ml\/min] 5...2984\nAnalogue start point ASP[ml\/min] 0...2400\nAnalogue end point AEP[ml\/min] 600...3000\nLow flow cut-off LFC[ml\/min] \u0026lt; 60\nVolumetric flow quantity monitoring\nPulse value 1...3000 ml\nPulse length[s] 0,008...2\nTemperature monitoring\nMeasuring range[°C] -20...80\nResolution[°C] 0.2\nSet point SP[°C] -19.2...80\nReset point rP[°C] -19.6...79.6\nAnalogue start point[°C] -20...60\nAnalogue end point[°C] 0...80\nIn steps of[°C] 0.2\nAccuracy \/ deviations\nFlow monitoring\nAccuracy (in the measuring range) ± (2 % MW + 0,5 % MEW)\nRepeatability ± 0,2% MEW\nTemperature monitoring\nAccuracy[K] ± 2,5 (Q \u0026gt; 0,5 l\/min)\nResponse times\nFlow monitoring\nResponse time[s] 0.15; (dAP = 0, T19)\nDelay time programmable dS, dr[s] 0...50\nDamping process value dAP[s] 0...5\nTemperature monitoring\nDynamic response T05 \/ T09[s] T09 = 40 (Q \u0026gt; 1 l\/min)\nSoftware \/ programming\nParameter setting options Flow monitoring; quantity meter; Preset counter; Temperature monitoring; hysteresis \/ window; normally open \/ normally closed; switching logic; current\/voltage\/pulse output; start-up delay; display can be deactivated; Display unit\nInterfaces\nCommunication interface IO-Link\nTransmission type COM2 (38,4 kBaud)\nIO-Link revision 1.1\nSDCI standard IEC 61131-9\nProfiles \nSmart Sensor - SSP 0 Generic Profiled Sensor\nFunction Device identification\nFunction Process data variable\nFunction Device diagnosis\nSIO mode yes\nRequired master port type A\nProcess data analogue 3\nProcess data binary 2\nMin. process cycle time[ms] 5\nSupported DeviceIDs \nType of operation DeviceID\ndefault 671\nOperating conditions\nAmbient temperature[°C] -10...60\nStorage temperature[°C] -25...80\nProtection IP 67\nTests \/ approvals\nEMC \nDIN EN 60947-5-9 \nCPA approval \nmodel number 007MI\naccuracy class -\nmaximum allowable error ± 2,5 % FS\nQ (min) 0,0003 m³\/h\nQ (t) -\nQ (max) 0,18 m³\/h\nShock resistance \nDIN IEC 68-2-27 20 g (11 ms)\nVibration resistance \nDIN IEC 68-2-6 5 g (10...2000 Hz)\nMTTF[years] 144\nPressure Equipment Directive Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request\nMechanical data\nWeight[g] 536.5\nDimensions[mm] Ø 54 \/ L = 110\nMaterials stainless steel (316L\/1.4404); PBT-GF20; PC; FKM; TPE\nMaterials (wetted parts) stainless steel (316L\/1.4404); PEEK; FKM\nProcess connection threaded connection G 1\/4 external thread DN6 flat seal\nDisplays \/ operating elements\nDisplay \nDisplay unit 6 x LED, green (ml\/min, l\/h, l, m³, °C, 10³)\nswitching status 2 x LED, yellow\nmeasured values alphanumeric display, 4-digit\nprogramming alphanumeric display, 4-digit\nRemarks\nRemarks \nMW = measured value\nMEW = Final value of the measuring range\nPack quantity 1 pcs.\nElectrical connection\nConnection Connector: 1 x M12; coding: A; Contacts: gold-plated\u003c\/p\u003e","brand":"KMSpare Link Pvt. Ltd.","offers":[{"title":"Default Title","offer_id":50548790788390,"sku":null,"price":0.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0947\/9097\/5782\/files\/SM4000_IFM_Flow_Meter_Industrial_Liquid_Flow_Sensor_KMSPARE.jpg?v=1768383186","url":"https:\/\/kmspare.com\/products\/sm4000-ifm-flow-meter-industrial-liquid-flow-sensor-kmspare","provider":"KMSpare Link Pvt. Ltd. - Complete Electronics \u0026 Smt Solutions","version":"1.0","type":"link"}